Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Integrate Spike with BMC Control-M

Integrate Spike with BMC Control-M to receive real-time alerts via Phone calls, SMS, Slack, MS Teams, and more when batch jobs fail or run late.

Overview

BMC Control-M is a workflow orchestration platform for scheduling and monitoring batch jobs across servers and applications.

With Spike's Control-M integration, an alert raised by Control-M becomes a Spike incident, and closing the alert in Control-M resolves it. Control-M does not send webhooks itself. It runs an alerts listener script that you provide, and that script posts the alert to Spike.

How it works

  • id is the Control-M alert id. It stays the same across every I and U delivery about one alert, so Spike uses it to match them. It may be sent as a string or a number (0 is an id), and Spike treats 2193, "2193" and " 2193 " as the same id. An empty value, a template variable that Control-M did not expand ($id, $ID, ${id}, {{id}}, %id%, %%ALERT_ID, <id>), or a word for no value (null, None, nil, undefined, NaN, n/a) is not an id.

  • eventType is I for a newly issued alert and U for an update. Matching is case-insensitive. An I delivery opens an incident. A U delivery never opens one: it joins the open incident with the same id, and is dropped when none is open. Any other or missing eventType opens an incident.

  • status is 0 Not_Noticed (New), 1 Noticed (Reviewed) or 2 Handled (Closed). 0 opens on I and joins on U. 1 joins and never closes. 2 resolves the open incident with the same id, and never opens one, whatever the eventType. status may be a string or a number; handled and closed count as 2, and noticed and reviewed as 1, in any case. An unknown status never resolves.

  • Without a valid id, Spike falls back to matching by title. Always send id: an alert without one cannot be reliably resolved.

  • Changes to eventType, status, severity, user, updateTime and notes between deliveries do not create a new incident.

  • The incident title is {message}: {jobName} on {host}, for example Ended not OK: nightly-invoice-export on prod-batch-agent-02.

    • message is Control-M's own sentence with whitespace collapsed. A variable Control-M did not expand counts as missing.

    • : {jobName} is dropped when message already names the job as a whole word, for example Job nightly-invoice-export failed on prod-batch-agent-02.

    • on {host} uses server when host is empty. It is dropped when message already names it, or when neither is present.

    • With an empty message the title is Control-M alert: {jobName} on {host}, then Control-M alert on {host}, then Control-M alert with no details.

    • The title is at most 200 characters. The message is cut at a word boundary with ... and the : {jobName} on {host} part is kept whole, unless that part alone is over 100 characters, in which case the title is cut plainly.

    • I, U, Noticed and Handled deliveries of one alert give the same title. id, times, status, severity and notes never appear in it.

Set up instructions

Step 1: Create a Control-M integration in the Spike dashboard and copy the webhook URL.

Create integration and service on our dashboard

Step 2: Configure the alerts listener in Control-M.

  1. Enable external alerts for your Control-M environment and choose the alert types to send, as described in BMC's "Sending events to external monitoring tools" tutorial. Set enableExternalAlerts to {"value": "true"} and externalAlertTypes to {"value": "Alerts"} with ctm config systemsettings::set, so that only job alerts are sent. Control-M system alerts use different status codes and have no id, so Spike does not support them: do not send them to this integration.

  2. Keep the default alert template. Control-M then passes each alert to the alerts listener script as arguments that use the field names in the table below (eventType, id, status, message, jobName, host and so on). Do not rename them.

  3. Save the listener script below on the machine that runs the alerts listener, and make it executable. Control-M starts it with /bin/sh, so it is written in plain POSIX shell. Replace SPIKE_WEBHOOK_URL with the URL from Step 1.

    • BMC documents more than one argument format, depending on the Control-M version and the useNewAlertFieldsFormat setting. The script accepts all three: a field name and its value as two arguments ("id: " then "2193 "), one argument with no spaces ("id:2193"), and one argument with spaces around the colon ("id : 2193").

    • An argument starts a new field only when the text before its first colon is a field name from the table below, or one of the template fields the script drops (closedByControlM, ticketNumber). Any other text, including a value that contains or ends in a colon such as Cause: disk full, is part of the current field's value.

    • When no argument names a known field, the script posts nothing and exits with status 2. It also exits non-zero when the post to Spike fails.

  4. Register the script with the alerts listener and start it: ctm run alerts:listener:environment::set <environment>, then ctm run alerts:listener:script::set <path to the script>, then ctm run alerts:listener::start.

  5. Confirm the argument format your listener uses. Set the listener's listenerLogLevel to debug, raise a test alert and check the Alerts listener log in $HOME/.ctm/python-logs/: it records the script's exit status, and 2 means the script found no field it knows. To see the exact arguments, set ARGS_LOG at the top of the script to a file path; the script then appends each argument it receives, one per line in brackets. Clear ARGS_LOG again once alerts arrive in Spike, because the file holds alert text.

The script needs jq and curl. A field with no value, such as user:, is sent as an empty string. Spaces around each name and value are trimmed.

The script produces this body for a newly issued alert:

When an operator handles (closes) the alert, the script sends the same alert with eventType U and status 2:

Fields

Send these fields and no others. All values are strings. id, eventType, status and message drive how alerts open and resolve; jobName, host and server build the title; severity sets the severity badge. The rest are kept on the incident.

Field
Control-M name
Meaning

eventType

call_type

Required. I = newly issued alert, U = update of an existing alert.

id

alert_id

Required. Unique key of the alert, the same across its I and U deliveries.

status

status

Required. 0 Not_Noticed, 1 Noticed, 2 Handled (Closed).

message

message

Required. The full text of the alert. It starts the incident title.

jobName

job_name

Job that raised the alert. Used in the title.

host

host_id

Agent host where the job ran. Used in the title.

server

data_center

Control-M/Server. Used in the title when host is empty.

severity

severity

V very urgent, U urgent, R regular. Sets the incident's severity badge: V → sev1, U → sev2, R → sev3. Never part of the title.

type

alert_type

R regular, B SLA (BIM). Kept only.

application

application

The job's application. Kept only.

subApplication

sub_application

The job's sub-application. Kept only.

fileName

memname

Job file name, often empty. Kept only.

runId

order_id

Order id of the job run. Kept only.

runNo

run_counter

Run counter of the job execution. Kept only.

runAs

run_as

OS user the job runs as. Kept only.

time

send_time

When the alert was issued, yyyymmddhhmmss. Kept only.

updateTime

last_time

When the alert was last modified. Changes on every U. Kept only.

user

last_user

The user who last changed the alert. Kept only.

notes

notes

Note text attached to the alert. Kept only.

On-premises Control-M/EM uses the older names in the "Control-M name" column (call_type, alert_id, data_center and so on). If your listener receives those, map them to the field names in the first column before posting.

Test the integration

  1. Make a Control-M job end not OK so that it raises an alert, or run the listener script by hand the way Control-M does, for example /bin/sh listener.sh "eventType: " "I " "id: " "2193 " "status: " "0 " "message: " "Ended not OK " "jobName: " "nightly-invoice-export " "host: " "prod-batch-agent-02 ". It posts the first body above, limited to the fields you pass.

  2. Verify a new incident titled Ended not OK: nightly-invoice-export on prod-batch-agent-02 is created in Spike.

  3. In Control-M, handle (close) the alert, or run the script again with "eventType: " "U " "status: " "2 " and the same id.

  4. Confirm Spike auto-resolves the incident for that id.