Integrate Spike with ITRS Geneos
Send ITRS Geneos alerts to Spike with a Script effect, so a breached dataview cell alerts your on-call team and resolves when Geneos clears it.
ITRS Geneos monitors servers, applications and middleware through Netprobes and a Gateway. When a dataview cell or headline crosses a threshold, the Gateway's Alerting subsystem runs an effect. Geneos has no built-in webhook, so you add a Script effect that posts the alert to Spike as JSON.
Once it is set up, an alert pages your on-call rotation when it fires, repeats and escalations land on the same incident, and the incident resolves itself when Geneos sends the clear.
Service and integration
Add the ITRS Geneos integration to a service and copy the webhook URL.
Create integration and service on our dashboardSet up the Script effect in Geneos
You need a host the Gateway runs on that has curl and jq installed and can reach hooks.spike.sh over HTTPS.
Step 1
On the Gateway host, create the script spike-geneos.sh, for example in /opt/geneos/scripts/, and make it executable with chmod +x spike-geneos.sh. Replace the URL with the webhook you copied from Spike.
#!/bin/bash
# Send a Geneos alert to Spike.sh
SPIKE_URL="https://hooks.spike.sh/********************/push-events"
jq -n \
--arg _ALERT "$_ALERT" \
--arg _ALERT_TYPE "$_ALERT_TYPE" \
--arg _CLEAR "$_CLEAR" \
--arg _ALERT_CREATED "$_ALERT_CREATED" \
--arg _ALERT_CLEARED "$_ALERT_CLEARED" \
--arg _HIERARCHY "$_HIERARCHY" \
--arg _RULE "$_RULE" \
--arg _SEVERITY "$_SEVERITY" \
--arg _VALUE "$_VALUE" \
--arg _VARIABLEPATH "$_VARIABLEPATH" \
--arg _GATEWAY "$_GATEWAY" \
--arg _PROBE "$_PROBE" \
--arg _NETPROBE_HOST "$_NETPROBE_HOST" \
--arg _MANAGED_ENTITY "$_MANAGED_ENTITY" \
--arg _SAMPLER "$_SAMPLER" \
--arg _DATAVIEW "$_DATAVIEW" \
--arg _ROWNAME "$_ROWNAME" \
--arg _COLUMN "$_COLUMN" \
--arg _HEADLINE "$_HEADLINE" \
--arg _REPEATCOUNT "$_REPEATCOUNT" \
'$ARGS.named' |
curl --silent --show-error --max-time 20 \
--header "Content-Type: application/json" \
--request POST \
--data @- \
"$SPIKE_URL"jq builds the JSON so that the quotes inside _VARIABLEPATH are escaped correctly. Do not assemble the body with plain string concatenation.
Step 2
Open the Gateway Setup Editor. In the navigation tree go to Alerting → Effects and add a new effect. Choose Script as its type and set:
Name
Spike
Script
The full path to the script, for example /opt/geneos/scripts/spike-geneos.sh
Leave the script's arguments empty. Geneos passes the alert to the script through environment variables, and the script reads them.
Step 3
Go to Alerting → Hierarchies and open the hierarchy that decides which data items alert (or create one). Add the Spike effect to the alert's Effects, and use it on the Alert, Clear and Resume notifications. Do not skip Clear: it is what resolves the Spike incident.
Step 4
Make sure a rule or Alerting → Alerts entry matches the data items you want to be paged for, and that it runs the hierarchy from step 3. Then Save the setup. The Gateway picks up the change on save.
Step 5
Trigger a test alert, or wait for a real one. The incident appears on the service in Spike within seconds.
Alternative: run the script from a Rule Action
If you raise alerts from rules rather than from an Alerting hierarchy, run the same script as a Script action:
In the Gateway Setup Editor, go to Actions, add an action named
Spike, choose Script as its type, and point it atspike-geneos.sh.In the rule that sets the data item's severity, run the
Spikeaction when the severity is raised (for examplerun "Spike"in the branch that setsseverity critical), and in the branch that sets the severity back took.
A Rule Action sends no _ALERT_TYPE. Spike then reads _SEVERITY instead: OK (or _CLEAR of TRUE) resolves the incident and any other severity fires. If the action does not also run when the severity returns to ok, incidents from it never resolve on their own.
Payload
The script sends one JSON object per alert. All values are strings, and a field Geneos leaves empty is sent as an empty string. This is the body of a firing alert:
And this is the body Geneos sends when the same alert clears:
Required and optional fields
_VARIABLEPATH
Yes
The identity of the alert. Firing, repeats, escalations and the clear all carry the same path, so they share one incident. When it is empty, Spike matches notifications by their plain title instead (see Incident title).
_ALERT_TYPE
Yes
Clear (or Delete) resolves the incident. Alert and Resume fire. Suspend and ThrottleSummary never open an incident. Compared case-insensitively. Empty when the script is run from a Rule Action.
_CLEAR
Yes
TRUE marks a clear. Used only when _ALERT_TYPE is empty; an Alert or Resume that carries TRUE still fires.
_SEVERITY
Yes
UNDEFINED, OK, WARNING, CRITICAL or USER. Shown at the start of a firing title when _VARIABLEPATH is present. When _ALERT_TYPE is empty, OK means recovered.
_VALUE
No
The reading that triggered the alert, shown in the title.
_ROWNAME, _COLUMN
No
Together they name the table cell in the title.
_HEADLINE
No
Names the item in the title when the alert is on a headline instead of a table cell.
_SAMPLER
No
Names the item in the title when there is no row, column or headline.
_DATAVIEW
No
Shown as "in dataview".
_MANAGED_ENTITY, _NETPROBE_HOST, _PROBE, _GATEWAY
No
Where the problem is. The first one that is not empty is used, in that order. _GATEWAY also names a throttle summary.
_ALERT, _HIERARCHY, _RULE, _REPEATCOUNT, _ALERT_CREATED, _ALERT_CLEARED
No
Kept on the incident as context. They do not affect matching.
Send the whole body as shown, even for fields you expect to be empty.
How Spike handles each notification
_ALERT_TYPE
What happens in Spike
Alert, Resume
Opens an incident, or adds an event to the one already open for the same _VARIABLEPATH
Clear, Delete
Resolves the open incident for the same data item: the same _VARIABLEPATH, or, when the alert has none, the same row, column, headline, sampler, dataview and managed entity. With nothing open, nothing is created
Suspend, ThrottleSummary
Never opens an incident
Empty (Rule Action)
_CLEAR of TRUE or _SEVERITY of OK resolves. Anything else fires
Identity is the data item, not the alert name. _ALERT includes the severity and escalation step, so it changes as an alert escalates and is not used for matching. A Critical alert that escalates, or whose value moves, stays one incident.
Incident title
Geneos sends no sentence describing the fault, so Spike builds the title from the fields.
Firing (Alert, Resume), with _VARIABLEPATH
Critical: Average_cpu percentUtilisation is 97 in CPU on db-prod-03
Firing, without _VARIABLEPATH
Average_cpu percentUtilisation in CPU on db-prod-03
Clear, or Rule Action back to OK
Cleared: Average_cpu percentUtilisation in CPU on db-prod-03
Suspend
Suspended: Average_cpu percentUtilisation in CPU on db-prod-03
Delete
Deleted: Average_cpu percentUtilisation in CPU on db-prod-03
ThrottleSummary
Throttle summary on GW_PROD_LDN
Nothing usable in the body
ITRS Geneos alert with no details
The title has these parts:
Severity is
_SEVERITYin title case.What is
_ROWNAMEand_COLUMN, else_HEADLINE, else_SAMPLER.Dataview is
_DATAVIEW, shown as "in dataview" unless it is empty or the same as what.Value is
_VALUE. Numbers from 10 up are shown whole with thousands separators, numbers below 10 with two significant digits. Text is quoted and capped at 80 characters.Where is the first non-empty of
_MANAGED_ENTITY,_NETPROBE_HOST,_PROBE,_GATEWAY.
The severity and value are shown only when _VARIABLEPATH is present. Without it, Spike can only match a repeat or clear by title, so it uses a plain title that never changes between notifications. A _VARIABLEPATH that still reads as an unexpanded variable name, such as $_VARIABLEPATH, counts as empty. Titles are capped at 200 characters.
Troubleshooting
No incident appears. Run the script by hand on the Gateway host with the variables set (
_VARIABLEPATH=x _ALERT_TYPE=Alert ./spike-geneos.sh) and checkcurlis not blocked by a proxy or firewall.Incidents do not resolve. Check that the
Spikeeffect is also used on the Clear notification (or, for a Rule Action, that the action also runs when the severity returns took). A clear resolves only the incident for the same data item, so it must come from the same cell or headline as the alert.Severity and value are missing from the title.
_VARIABLEPATHarrived empty, so Spike fell back to the plain title. Confirm the script passes--arg _VARIABLEPATH "$_VARIABLEPATH"and thatjqis installed. Repeats and clears still match the open incident by that plain title.
Last updated