Integrate Spike with Observe
Send Observe monitor alarms to Spike with a webhook action, so a firing alarm alerts your on-call team and resolves when the alarm condition ends.
Observe is an observability platform for logs, metrics and traces. Its monitors watch your data and raise an alarm when a condition is met. A monitor sends its alarms to an action, and a webhook action can post them to any URL.
Point a webhook action at a Spike integration URL and a firing alarm pages your on-call rotation, repeat notifications land on the incident already open, and the incident resolves itself when Observe reports the alarm condition has ended.
What Spike does with each alarm event
Every delivery carries event_type, filled from {{alert.type.eventType}}, and that field decides what Spike does with it. It is compared ignoring spaces and letter case.
event_type
What Spike does
NewAlarm
Opens an incident and pages.
Reminder
A repeat notification for an alarm that is still active. It joins the open incident with the same alert_id, and opens an incident when none is open.
AlarmConditionEnded
The alarm condition has cleared. Resolves the open incident with the same alert_id. Dropped when nothing is open.
Any other or missing event_type opens an incident and never resolves one.
Incident identity
Spike identifies the incident by alert_id, filled from {{alert.id}}: the alarm's UUID, not the monitor's numeric id. Observe is expected to repeat it on NewAlarm, Reminder and AlarmConditionEnded, so one alarm's whole life reads as one Spike incident: it pages once, reminders join it, and the end notification resolves it.
A value counts as an id when it is not empty and is not a template variable left unexpanded (for example $alert_id, ${alert_id}, {{alert.id}} or %alert_id%). When alert_id is missing or arrives unexpanded, Spike has no identity to go on and matches on the incident title instead. The title never holds readings, timestamps, ids or URLs, so a repeat of the same alarm joins the open incident. It also means that different alarms with the same title (for example two group-by alarms of one monitor) are one incident, and the second does not page.
Without a usable alert_id on both the opening and the ending notification, AlarmConditionEnded joins the open incident but does not resolve it. Resolving needs the same alert_id on both.
What the incident title looks like
Your monitor title.
summary, filled from{{monitor.variables.title}}, is the incident title, with whitespace collapsed. For exampleHigh CPU utilization for container checkout-api in prod-us-east-1.No monitor title. When
summaryis empty or an unexpanded variable, the title ismonitor_name, for exampleContainer CPU utilization.Nothing usable.
Observe alert with no details.Recovery.
AlarmConditionEndedgivesAlarm ended:followed by the same title, for exampleAlarm ended: High CPU utilization for container checkout-api in prod-us-east-1. Spike matches it to the open incident throughalert_id. With no id it joins the open incident through the plain firing title but does not resolve it.Length. The whole title, prefix included, is capped at 200 characters, cut at a word boundary and ended with
....
alert_message, description, timestamps and URLs are never part of the title. They are kept on the incident for responders.
Severity
Spike reads the top-level severity field, filled from {{alert.severity.level}}:
Critical
SEV1
Error
SEV2
Warning
SEV2
Informational
SEV3
NoData
Left unset
Set up instructions
Step 1: Create an Observe integration on the Spike dashboard and copy the webhook URL.
Create integration and service on our dashboardStep 2: Create a webhook action in Observe.
From the left rail open Monitors, click View shared actions, then New shared action.
Set Action Type to Webhook.
Paste the Spike webhook URL into the URL field. This field is required.
Accept the default Method of
POSTand, under Headers, addContent-Type: application/json.Paste the body from the next section into the Body field, replacing the default template. This field is required.
Click Create Shared Action.
Step 3: Attach the action to your monitors.
Open the monitor, or create a new one, and scroll to Notification actions.
Add the webhook action you just created. Beneath the action, turn on Send an update when the monitor has stopped triggering so Observe sends
AlarmConditionEndedand Spike can resolve the incident.Set the monitor's title variable (
monitor.variables.title) to the sentence you want as the incident title. Keep readings that change between notifications out of it.Save the monitor.
Webhook body
Paste this body into the action. Observe fills in the {{…}} variables when it sends the alarm. Do not add, rename or drop fields.
Fields
event_type
Yes
NewAlarm opens, Reminder joins, AlarmConditionEnded resolves.
alert_id
Strongly recommended
The alarm UUID. Identity of the incident across all three events.
summary
No
Your own title sentence. Used as the incident title when not empty.
monitor_name
Yes
Title when summary is empty.
severity
No
Sets the incident severity, see the table above.
alert_message
No
Your longer alert message. Shown on the incident, never in the title. Not named message on purpose: a top-level message makes Spike skip the Observe parser.
description
No
Monitor description. Display only.
monitor_id
No
The monitor's numeric id. Display only, not an alarm identity.
monitor_type
No
Count, Promote, Threshold or Anomaly. Display only.
is_active
No
true while the condition is triggering, false after it clears. Display only; event_type decides.
start_time
No
When the condition started. Display only.
end_time
No
When the condition ended, empty while active. Display only.
timestamp
No
When Observe evaluated this notification. Changes on every delivery. Display only.
alert_url
No
Link to the alarm in the Observe console. Display only.
monitor_url
No
Link to the monitor in the Observe console. Display only.
Example payloads
A firing alarm (NewAlarm):
The same alarm once the condition has cleared (AlarmConditionEnded):
Test the integration
Trigger a test notification from the action in Observe, or send the firing example above to your Spike webhook URL with curl. An incident titled High CPU utilization for container checkout-api in prod-us-east-1 should open. Send the recovery example with the same alert_id and it should resolve.
Troubleshooting
The incident never resolves. Send an update when the monitor has stopped triggering is off on the monitor's action, the recovery's
alert_iddiffers from the opening one, oralert_idis missing or unexpanded on either notification.Every reminder opens a new incident.
alert_idis missing or arrives unexpanded, so Spike is matching on the title. Confirm the body above is pasted as written, and keep changing readings out of the monitor title.The title is the monitor name instead of your sentence.
monitor.variables.titleis empty on that monitor.Spike ignores the fields. Check the body has no top-level
messagefield.
Last updated