Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Integrate Spike with OpenText SiteScope

Send OpenText SiteScope alerts to Spike so a monitor over its threshold alerts your on-call team, and resolves when the monitor returns to good.

OpenText SiteScope (formerly Micro Focus SiteScope, and HP SiteScope before that) is agentless infrastructure and application monitoring. Monitors run on a schedule against servers, databases, URLs, services and the network, and each run puts the monitor into one of three threshold categories — good, warning or error.

With this integration, a monitor going to error or warning opens an incident in Spike and escalates it through your policy, every later run of that same monitor lands on the incident that is already open instead of paging again, and the monitor going back to good resolves it.

Nothing is installed. SiteScope's own REST alert action posts to a Spike webhook URL, so the only thing to configure is one alert in SiteScope.

SiteScope has no fixed webhook payload. The body of a REST alert action is a template you paste, written in SiteScope's alert properties, so this guide gives you the exact body to paste. Spike reads the keys below and nothing else — do not rename monitor_id or category.

What Spike does with a SiteScope alert

category is the whole decision, and it is the only field Spike treats as a verdict.

category

What Spike does

error

Opens an incident and escalates it, or adds the reading to the incident already open for that monitor

warning

The same. Which of the two is worth waking somebody for is an alert rule's decision, not the payload's

good

Resolves the open incident for that monitor

The comparison is case-insensitive, so error, Error and ERROR all fire and good, Good and GOOD all resolve. A category Spike has never been shown — or a payload with no category at all — is treated as firing, because failing to page somebody is the worse mistake.

state is never consulted for this. It is the reading the monitor took ("95% full, 2.1GB free", "no response"), not a status word, and a recovery's reading looks nothing like one.

Incident identity

Spike identifies the incident by monitor_id — SiteScope's <monitorUUID>, the monitor's own stable id. SiteScope repeats it on every alert about that monitor, so one disk filling up reads as one incident: it pages once at 11:42, the 11:47 run lands on it, and the good at 12:05 resolves it.

That matters more here than for most tools, because SiteScope re-evaluates state on every scheduled run. The readings move while one problem stays one problem, and only the monitor's id gets that right.

Incident title

SiteScope writes no summary, description or message — there is no field in the payload where SiteScope says in prose what is wrong — so Spike builds the title: what, then how much, then where, with the host last.

The what is monitor_name, falling back to monitor_type and then to alert_name. The how much is state, as SiteScope wrote it. The where is target_host, falling back to group for a monitor with no remote target — a URL monitor measures a URL, not a machine — and dropped entirely when SiteScope sends neither:

When state is empty, or just repeats the category, the title says the state in words instead:

A recovery is written as one, without readings, because "71% full, 12.4GB free" is true of a healthy disk and says nothing at the moment a page goes away:

And a monitor Spike has no monitor_id for gets the plain, stable form — no readings, because the title is what the next alert is matched on:

Titles are capped at 200 characters, whitespace is collapsed, and they carry no ids, no URLs and no timestamps; those are all on the incident page. The host is kept whole when the title is shortened, unless the host itself runs past 100 characters. A URL in a monitor name or a status string — SiteScope names a URL monitor after its URL — is shown as host and path only, without the scheme, any user:password@, query string or fragment, so credentials in a monitored URL never reach a phone call, SMS or Slack message.

A status string long enough to be prose — a URL monitor can report the first line of the error page it got back — is reduced to the fault it names rather than cut off mid-sentence: the server returned 502 Bad Gateway and the response body said that the upstream connection was reset while ... becomes URL - checkout: the server returned 502 Bad Gateway on prod-lb-01. The whole string stays on the incident page.

Use a Title Remapper if your team reads SiteScope alerts differently — by group and monitor type, for instance:

Severity

Spike does not read a severity from the SiteScope payload. category decides whether an incident opens and whether it resolves, and it never sets the severity badge, so a warning and an error open at your integration's default.

If you want SiteScope's categories on the badge, write an alert rule on category. Alert rules can also route the incident to another service or escalation policy, or suppress it entirely. Read more about priority and severity.

Prerequisites

  • A SiteScope user with permission to create alerts — SiteScope's Alerts permission, usually an administrator

  • SiteScope's REST alert action, which is available from the Action Type list when you add an alert action

  • An OpenText SiteScope integration in Spike, and its webhook URL

  • Outbound HTTPS from the SiteScope server to hooks.spike.sh. SiteScope calls out to Spike, so nothing has to be opened inbound

Step 1 — Create the integration in Spike

In Spike, go to Integrations → Add integration → OpenText SiteScope, attach it to a service and an escalation policy, and copy the webhook URL. It looks like https://hooks.spike.sh/<your-token>/push-events.

Create integration and service on our dashboard

Step 2 — Create the alert in SiteScope

  1. Sign in to SiteScope at https://<your-sitescope-server>:8443/SiteScope and open the Monitors context.

  2. Create the alert. In the monitor tree on the left, right-click the group, the monitor or the SiteScope root you want the alert to cover and select New → Alert. The New Alert dialog opens.

  3. General Settings. Give the alert a Name — this is required, and it is what arrives in alert_name. Spike - error and good describes what it does.

  4. Alert Targets. Tick the groups and monitors this alert applies to. The node you right-clicked is ticked already; tick the whole SiteScope root to cover every monitor you have.

  5. Alert Actions. Select New Alert Action. In the Action Type list of the Alert Action wizard, choose REST, then select Next.

  6. Action Settings. Fill in the four fields that matter, all of them required:

    • URL — the webhook URL from Step 1

    • HTTP Method — POST

    • Format Type — JSON

    • Request Body — the template in Step 3

  7. Status Trigger. This is the step that decides what reaches Spike. Tick Error, Warning and Good, and set the trigger frequency to alert always, after the condition has occurred at least once so a monitor that stays in error keeps reporting its reading.

  8. Save the alert action, then Save the alert.

The dialog labels differ a little between SiteScope versions, and older versions read the body from a template file under <SiteScope root>/templates.rest instead of from a field in the dialog. The four things to set are the same either way: the URL, POST, JSON, and the body below.

Step 3 — Paste the request body

This is the body Spike reads. Paste it into Request Body exactly as it is — the keys on the left are what Spike looks for, and the values on the right are SiteScope's own alert properties, which SiteScope replaces when the alert fires.

What each key is for, and which ones Spike cannot do without:

Key
SiteScope property
Required
What Spike does with it

monitor_id

<monitorUUID>

Required

Incident identity. Groups every alert about one monitor onto one incident, and is what the recovery resolves

category

<category>

Required

error and warning open an incident, good resolves it

monitor_name

<name>

Required

The "what" — the head of the incident title

state

<state>

Recommended

The reading behind the breach, and the "how much" in the title

target_host

<targetHost>

Recommended

The "where" — the host the monitor was measuring

group

<group>

Recommended

The "where" for a monitor with no host, such as a URL monitor

monitor_type

<monitorTypeDisplayName>

Optional

The "what", when the monitor has no name

alert_name

<alertName>

Optional

The "what", when there is no name and no type

sitescope_server

<siteScopeHost>

Optional

Context on the incident page. Which SiteScope sent the alert

time

<time>

Optional

Context on the incident page. Titles carry no timestamps

<alertName> is spelled <alert::name> in some SiteScope versions. If alert_name arrives as the literal text <alertName> on your first incident, swap it for <alert::name>. The same goes for any other property your version does not know — Spike treats an unsubstituted property as a missing value rather than as a name, so a wrong spelling costs a fallback, never a grouped incident.

Step 4 — Confirm it end to end

Trigger a real state change on one monitor — pause and resume it, or point a URL monitor at a port nothing is listening on — and watch for all three moments:

  1. The monitor goes to error and an incident opens in Spike with the monitor, the reading and the host in its title, on the service you attached, escalating through your policy.

  2. The monitor runs again while still in error, and the new reading lands on the same incident instead of paging again.

  3. The monitor goes back to good and the incident resolves itself.

If the first step works and the third does not, the Status Trigger is the thing to check: Good has to be ticked on an alert action pointing at the same Spike URL.

Payload reference

Everything SiteScope posts is kept on the incident, so every key in the body is available to alert rules and the Title Remapper as data.body.<key>.

A monitor crossing its threshold, which opens the incident:

The same monitor back inside its thresholds, which resolves it. Note that monitor_id is the one the error carried — that is what joins the two:

Things worth knowing

  • One alert can cover every monitor you have. Tick the SiteScope root under Alert Targets and the one REST alert action covers the whole estate. There is no per-monitor setup.

  • Several Spike integrations are fine. If different teams own different parts of the estate, create one Spike integration per team and one SiteScope alert per integration, with that team's groups ticked under Alert Targets.

  • Resolving in Spike does not touch SiteScope. The monitor stays in error in SiteScope until it measures its way out of it.

  • SiteScope's own alert actions are separate. The email, SNMP and script actions you already have keep working; the REST action is additional, not a replacement.

  • One monitor per request. SiteScope alerts fire per monitor state change, so each delivery is about one monitor.

FAQs

Will incidents in Spike auto-resolve when a monitor recovers?

Yes, as long as Good is ticked under Status Trigger on a REST alert action pointing at the Spike URL. Spike resolves on "category": "good" and on nothing else — not on a healthier state, and not on a change of category from error to warning.

If your SiteScope only allows one status trigger per alert action, create a second REST alert action with the same URL and the same request body and tick Good on that one.

Does Spike group repeated alerts from the same monitor?

Yes. Every alert carrying the same monitor_id lands on the incident already open for that monitor, with the new reading on its event list, and your rotation is not paged again. If SiteScope sends no usable monitor_id, Spike groups on the incident title instead, which is why that title is kept identical across runs and carries no readings.

Every run of the monitor opens its own incident

Open two of the incidents in Spike and compare monitor_id on the payload. If it is missing, empty, or the literal text <monitorUUID>, your SiteScope version does not substitute that property — Spike then matches on the title, and the titles have to be identical, so check that the monitor's name and host are not themselves changing between runs.

If monitor_id differs between the two, they are genuinely two monitors. Two monitors are two incidents by design, even when they watch the same host.

Do warnings open incidents?

Yes. warning and error both open one, and the title says what the monitor measured rather than which of the two it was. Use an alert rule on category if you want warnings routed somewhere quieter, given a lower severity, or suppressed.

Can I add fields to the request body?

Yes — anything you add is kept on the incident and is readable by alert rules and the Title Remapper as data.body.<key>. What you should not do is rename or remove the ten keys above: monitor_id and category are read under those names only, and dropping monitor_name costs the title the monitor it is about.

An incident titled "SiteScope alert with no details" opened

The delivery named no monitor, no host and no state — usually a request body whose properties SiteScope substituted nothing into, so every value arrived as the literal text that was pasted. Check the payload on the incident page against the body in Step 3, and check the property spellings against your SiteScope version. Spike opens an incident for an unreadable delivery rather than dropping it silently. Such an incident does not resolve on its own: a good delivery that names no monitor cannot show which monitor recovered, so resolve it in Spike once the template is fixed.

Nothing arrives in Spike

Check these in order. That the URL on the alert action is the full https://hooks.spike.sh/<your-token>/push-events with nothing appended, and that the integration has not been archived in Spike. That HTTP Method is POST and Format Type is JSON. That at least one status is ticked under Status Trigger — an alert action with no trigger fires for nothing. That the monitor you are testing is inside the Alert Targets you ticked. And that the SiteScope server can reach hooks.spike.sh on port 443; SiteScope's Tools → Alert test and its alert log, <SiteScope root>/logs/alert.log, say whether the POST left the server.

Can I customise the incident title?

Yes, with a Title Remapper over any key in the body, for example {{data.body.monitor_name}} on {{data.body.target_host}}. If your monitors have no monitor_id, keep the remapped title free of anything that moves between runs — readings, counters, timestamps — because the title is then what Spike matches the next alert on.

Disclaimer: These integration instructions are offered independently by Spike.sh, and Spike.sh is not affiliated with nor a partner of Open Text Corporation.