Integrate Spike with OpenText SiteScope
Send OpenText SiteScope alerts to Spike so a monitor over its threshold alerts your on-call team, and resolves when the monitor returns to good.
OpenText SiteScope (formerly Micro Focus SiteScope, and HP SiteScope before that) is agentless infrastructure and application monitoring. Monitors run on a schedule against servers, databases, URLs, services and the network, and each run puts the monitor into one of three threshold categories — good, warning or error.
With this integration, a monitor going to error or warning opens an incident in Spike and escalates it through your policy, every later run of that same monitor lands on the incident that is already open instead of paging again, and the monitor going back to good resolves it.
Nothing is installed. SiteScope's own REST alert action posts to a Spike webhook URL, so the only thing to configure is one alert in SiteScope.
What Spike does with a SiteScope alert
category is the whole decision, and it is the only field Spike treats as a verdict.
category
What Spike does
error
Opens an incident and escalates it, or adds the reading to the incident already open for that monitor
warning
The same. Which of the two is worth waking somebody for is an alert rule's decision, not the payload's
good
Resolves the open incident for that monitor
The comparison is case-insensitive, so error, Error and ERROR all fire and good, Good and GOOD all resolve. A category Spike has never been shown — or a payload with no category at all — is treated as firing, because failing to page somebody is the worse mistake.
state is never consulted for this. It is the reading the monitor took ("95% full, 2.1GB free", "no response"), not a status word, and a recovery's reading looks nothing like one.
Incident identity
Spike identifies the incident by monitor_id — SiteScope's <monitorUUID>, the monitor's own stable id. SiteScope repeats it on every alert about that monitor, so one disk filling up reads as one incident: it pages once at 11:42, the 11:47 run lands on it, and the good at 12:05 resolves it.
That matters more here than for most tools, because SiteScope re-evaluates state on every scheduled run. The readings move while one problem stays one problem, and only the monitor's id gets that right.
Incident title
SiteScope writes no summary, description or message — there is no field in the payload where SiteScope says in prose what is wrong — so Spike builds the title: what, then how much, then where, with the host last.
The what is monitor_name, falling back to monitor_type and then to alert_name. The how much is state, as SiteScope wrote it. The where is target_host, falling back to group for a monitor with no remote target — a URL monitor measures a URL, not a machine — and dropped entirely when SiteScope sends neither:
When state is empty, or just repeats the category, the title says the state in words instead:
A recovery is written as one, without readings, because "71% full, 12.4GB free" is true of a healthy disk and says nothing at the moment a page goes away:
And a monitor Spike has no monitor_id for gets the plain, stable form — no readings, because the title is what the next alert is matched on:
Titles are capped at 200 characters, whitespace is collapsed, and they carry no ids, no URLs and no timestamps; those are all on the incident page. The host is kept whole when the title is shortened, unless the host itself runs past 100 characters. A URL in a monitor name or a status string — SiteScope names a URL monitor after its URL — is shown as host and path only, without the scheme, any user:password@, query string or fragment, so credentials in a monitored URL never reach a phone call, SMS or Slack message.
Use a Title Remapper if your team reads SiteScope alerts differently — by group and monitor type, for instance:
Severity
Spike does not read a severity from the SiteScope payload. category decides whether an incident opens and whether it resolves, and it never sets the severity badge, so a warning and an error open at your integration's default.
If you want SiteScope's categories on the badge, write an alert rule on category. Alert rules can also route the incident to another service or escalation policy, or suppress it entirely. Read more about priority and severity.
Prerequisites
A SiteScope user with permission to create alerts — SiteScope's Alerts permission, usually an administrator
SiteScope's REST alert action, which is available from the Action Type list when you add an alert action
An OpenText SiteScope integration in Spike, and its webhook URL
Outbound HTTPS from the SiteScope server to
hooks.spike.sh. SiteScope calls out to Spike, so nothing has to be opened inbound
Step 1 — Create the integration in Spike
In Spike, go to Integrations → Add integration → OpenText SiteScope, attach it to a service and an escalation policy, and copy the webhook URL. It looks like https://hooks.spike.sh/<your-token>/push-events.
Step 2 — Create the alert in SiteScope
Sign in to SiteScope at
https://<your-sitescope-server>:8443/SiteScopeand open the Monitors context.Create the alert. In the monitor tree on the left, right-click the group, the monitor or the SiteScope root you want the alert to cover and select New → Alert. The New Alert dialog opens.
General Settings. Give the alert a Name — this is required, and it is what arrives in
alert_name.Spike - error and gooddescribes what it does.Alert Targets. Tick the groups and monitors this alert applies to. The node you right-clicked is ticked already; tick the whole SiteScope root to cover every monitor you have.
Alert Actions. Select New Alert Action. In the Action Type list of the Alert Action wizard, choose REST, then select Next.
Action Settings. Fill in the four fields that matter, all of them required:
URL — the webhook URL from Step 1
HTTP Method —
POSTFormat Type —
JSONRequest Body — the template in Step 3
Status Trigger. This is the step that decides what reaches Spike. Tick Error, Warning and Good, and set the trigger frequency to alert always, after the condition has occurred at least once so a monitor that stays in error keeps reporting its reading.
Save the alert action, then Save the alert.
Step 3 — Paste the request body
This is the body Spike reads. Paste it into Request Body exactly as it is — the keys on the left are what Spike looks for, and the values on the right are SiteScope's own alert properties, which SiteScope replaces when the alert fires.
What each key is for, and which ones Spike cannot do without:
monitor_id
<monitorUUID>
Required
Incident identity. Groups every alert about one monitor onto one incident, and is what the recovery resolves
category
<category>
Required
error and warning open an incident, good resolves it
monitor_name
<name>
Required
The "what" — the head of the incident title
state
<state>
Recommended
The reading behind the breach, and the "how much" in the title
target_host
<targetHost>
Recommended
The "where" — the host the monitor was measuring
group
<group>
Recommended
The "where" for a monitor with no host, such as a URL monitor
monitor_type
<monitorTypeDisplayName>
Optional
The "what", when the monitor has no name
alert_name
<alertName>
Optional
The "what", when there is no name and no type
sitescope_server
<siteScopeHost>
Optional
Context on the incident page. Which SiteScope sent the alert
time
<time>
Optional
Context on the incident page. Titles carry no timestamps
Step 4 — Confirm it end to end
Trigger a real state change on one monitor — pause and resume it, or point a URL monitor at a port nothing is listening on — and watch for all three moments:
The monitor goes to error and an incident opens in Spike with the monitor, the reading and the host in its title, on the service you attached, escalating through your policy.
The monitor runs again while still in error, and the new reading lands on the same incident instead of paging again.
The monitor goes back to good and the incident resolves itself.
If the first step works and the third does not, the Status Trigger is the thing to check: Good has to be ticked on an alert action pointing at the same Spike URL.
Payload reference
Everything SiteScope posts is kept on the incident, so every key in the body is available to alert rules and the Title Remapper as data.body.<key>.
A monitor crossing its threshold, which opens the incident:
The same monitor back inside its thresholds, which resolves it. Note that monitor_id is the one the error carried — that is what joins the two:
Things worth knowing
One alert can cover every monitor you have. Tick the SiteScope root under Alert Targets and the one REST alert action covers the whole estate. There is no per-monitor setup.
Several Spike integrations are fine. If different teams own different parts of the estate, create one Spike integration per team and one SiteScope alert per integration, with that team's groups ticked under Alert Targets.
Resolving in Spike does not touch SiteScope. The monitor stays in error in SiteScope until it measures its way out of it.
SiteScope's own alert actions are separate. The email, SNMP and script actions you already have keep working; the REST action is additional, not a replacement.
One monitor per request. SiteScope alerts fire per monitor state change, so each delivery is about one monitor.
FAQs
Disclaimer: These integration instructions are offered independently by Spike.sh, and Spike.sh is not affiliated with nor a partner of Open Text Corporation.
Last updated